Self-levelling compound is a cement-based powder that, once mixed with water, flows out across a floor to create a flat, smooth base for tiles, vinyl, timber or carpet. You may also see it called self-leveling compound, self-levelling concrete or floor leveller.

It is an underlayment, not a finished floor. It corrects an uneven slab or subfloor so the floor covering above it can be installed properly, and it must always be covered.

This guide explains where self-levelling compound works, how thick it can go, how to prepare and pour it, how long it takes to dry and how many bags you need. Figures quoted for LEVELMAX ProFlow are taken at 23 °C and 50% relative humidity; always check the current Technical Data Sheet (TDS) for your product.

What is self-levelling compound?

A self-levelling compound combines cement, fine aggregate and polymers. The polymers help it flow, bond to a primed substrate and resist cracking as it cures. Poured at the right consistency, it finds its own level and needs only light spreading.

Despite the name “self-levelling concrete”, it is a thin levelling layer placed over an existing slab or subfloor. It does not replace structural concrete, and it is not designed to be left exposed as a wearing surface.

When should you use it?

Use a self-levelling compound when the substrate is too uneven for the floor covering or adhesive you plan to use. Typical situations include:

  • Levelling a concrete slab before glue-down timber, vinyl or tiles
  • Smoothing a screed with ridges, dips or trowel marks
  • Creating a flat base over existing ceramic tiles that are sound and well bonded
  • Covering underfloor heating elements (with at least 5 mm of compound above the highest point of the element)
  • Levelling a rigid, securely fixed timber subfloor such as plywood or Yellow Tongue particleboard

Which substrates are suitable?

Substrate Suitable? Preparation and primer
Concrete slab or sand-cement screed Yes Grind to at least CSP 3, vacuum, prime with Primer X Concentrate diluted 1:1
Existing ceramic tiles Yes, if sound and well bonded Degrease, abrade to at least CSP 3, vacuum, use a primer suited to non-absorbent surfaces
Plywood, particleboard, Yellow Tongue Yes, if rigid, dry and securely fixed Prime with Primer X Timber, undiluted, at least 1.5 mm total wet film
Flexible, loose, damp or deforming timber No Fix the subfloor first; primer and compound cannot compensate for movement
Exposed outdoor areas or driveways No Use only in covered external areas where a floor finish will protect it

Every substrate must be clean, sound and dry, and free from laitance, oil, grease, wax, curing compounds, old paint, adhesive residues and release agents. For primer choice and application, see Self-Levelling Compound Primer: Do You Need It?

How thick can self-levelling compound be?

Thickness depends on the product. LEVELMAX ProFlow can be applied from 1 mm to 40 mm in a single coat. For greater depths, apply it in layers: let each layer set and dry, then prime it again before pouring the next.

Over underfloor heating, allow at least 5 mm of compound above the highest point of the heating element, and keep the heating switched off while the compound cures.

Check slab moisture first

Self-levelling compound and acrylic primers are not moisture barriers. Test the slab in accordance with AS 1884. We recommend in-situ relative humidity probes to ASTM F2170, with a result of 75% RH or below and no rising damp.

Apply a suitable damp-proof primer first where readings exceed 75% RH, on slabs in contact with the ground, on new concrete, or under moisture-sensitive finishes such as timber. Let it dry completely before priming for the compound. For more detail, read Concrete Slab Moisture Testing Before Flooring.

How to apply self-levelling compound

  1. Prepare the surface. Grind to at least CSP 3 and remove dust with an industrial HEPA vacuum.
  2. Seal gaps. Fill small holes, cracks and openings at walls with expanding foam or sand so the compound cannot escape. Leaks can leave the finished surface uneven.
  3. Apply a damp-proof primer if required, and let it dry completely.
  4. Prime. Use Primer X Concentrate (1:1) on mineral substrates and allow about 2 hours to dry, or Primer X Timber on timber and allow 3–4 hours. Do not pour onto primer that is wet, tacky or patchy.
  5. Mix. Add one 20 kg bag of ProFlow to 4.8 L of clean, cool water. Mix with a drill mixer at around 300 rpm for at least 3 minutes, rest for 2 minutes, then remix briefly.
  6. Pour and spread within the 20–30 minute working time.
  7. Protect while curing. Keep doors and windows closed and the floor out of direct sun for 24 hours, then ventilate normally.
  8. Finish. Once dry, sand lightly, vacuum, and install the floor covering when the TDS conditions are met.

Do not mix by hand or in a concrete mixer, never add extra water, and never add water once the mix has started to set. Do not add cement, lime, gypsum or other additives, and do not mix different brands of compound.

How long does self-levelling compound take to dry?

Stage ProFlow at 23 °C / 50% RH
Working time after mixing 20–30 minutes
Initial set 60–90 minutes
Light foot traffic Approx. 3 hours
Floor coverings From 24 hours

Thicker pours, low temperatures and high humidity all extend these times. Apply between +5 °C and +35 °C. Light foot traffic is not the same as being ready for a floor covering: confirm the slab and site conditions meet the flooring and adhesive requirements before installation.

How many bags do you need?

Allow approximately 1.65 kg of ProFlow per m² per mm of thickness:

Bags = area (m²) × thickness (mm) × 1.65 ÷ 20

For example, a 20 m² room at 5 mm needs about 165 kg, or 9 bags. Use the average thickness across the room, not the deepest low point, and add an allowance for the substrate profile and site wastage.

Thickness Coverage per 20 kg bag
5 mm 2.4 m²
10 mm 1.2 m²
20 mm 0.6 m²
30 mm 0.4 m²
40 mm 0.3 m²

Common mistakes and what they cause

  • Too much water: surface dusting, weakness and cracking
  • Skipping primer, or pouring onto primer that is not dry: hollow spots, pinholes and debonding
  • Draughts or direct sun while curing: cracking
  • Priming over a damp-proof coat that has not dried: cracking, often with brush marks visible on the underside
  • Under-mixing or uneven water between bags: lumps and patchy colour

How to choose a self-levelling compound

Compare products on more than price:

  • Classification: EN 13813 ratings show strength. ProFlow is CT-C30-F6, meaning compressive strength above 30 MPa and flexural strength above 6 MPa at 28 days.
  • Thickness range per coat for your job
  • Compatibility with your primer, adhesive and floor covering
  • Low VOC and low dust for occupied or Green Star projects
  • Acoustic requirements: in apartments, assess the complete floor build-up against the project's acoustic requirements, not the levelling compound alone

ProFlow on real projects

See how ProFlow was used to prepare subfloors on Sydney apartment and townhouse projects:

For low VOC and Green Star documentation across the range, see Low VOC Flooring Products: Documents and Site Safety Checks.

Talk to our technical team

LEVELMAX ProFlow is stocked at our Greenacre warehouse in Sydney with trade pricing for flooring and tiling professionals. For a project quote, send the floor area, average thickness, substrate, planned floor covering and required date. Call 1300 601 898 or request a trade quote.

Share This

Back to blog

Leave a comment

Please note, comments need to be approved before they are published.